The CI40 series AC contactor is a high-performance electrical component designed for power circuits operating at frequencies of 50Hz or 60Hz. With a rated working voltage of up to 690V (or 1140V) and a maximum rated working current of 1000A, this contactor is ideal for connecting and breaking circuits in various industrial applications. When paired with the appropriate thermal relay or electronic protection device, it forms a reliable motor starter, ensuring protection against potential overloads. The CI40 contactor complies with international standards including GB14048.4 and IEC60947-4-As a leading China supplier and factory of electrical components, we are committed to delivering high-quality products that meet global standards and customer needs

    Type and meaning

    CJ40 series AC contactor

    Type and meaning

    The auxiliary code is composed of 5 parts, which are selected in the following order as needed:

    First part: “y” means general type, “N” (can be omitted) means reversible type;
    Second part: 1 digit is used to indicate the number of poles of the main circuit: 3 and 4 respectively indicate 3 and 4 poles, and 3 can be omitted;
    Third part: 2 digits are used to indicate the highest rated working voltage, "06" (which can be omitted) indicates 690V, "11" indicates 1140V;
    Fourth part: Indicates the rated control power supply voltage, with letters "Ac" indicating alternating current 50 Hz and "Dc" indicating direct current. The value of the rated control power supply voltage is behind the letters, but “AC380” can be omitted;
    Fifth part: The letter "□" and two digits are used together to indicate the type and number of auxiliary contacts, of which the first digit indicates the number of pairs of normally open auxiliary contacts and the second digit indicates the number of pairs of normally closed auxiliary contacts, but “□42” can be omitted.
    Note: This item includes two parts, i.e., the number of main contacts and the number of auxiliary contact, which are indicated by number respectively, as shown in the diagram below. ( -□□-□□ ) indicates: - number of normally open main contacts, number of normally closed main contacts - number of normally open auxiliary contacts, number of normally closed auxiliary contacts.

    Normal working conditions and installation conditions

    The altitude of the installation site should not exceed 2000m;
    The ambient air temperature should not be higher than +40℃ and not be lower than -5℃;
    When the highest temperature is +40℃, the relative humidity of the air on the installation site should not be higher than 50%; A higher relative humidity is allowed at a lower temperature; In the wettest month, the monthly average minimum temperature should not exceed +20℃, and the average maximum relative humidity should not exceed 90%. Measures should be taken for condensation on the product due to temperature change;
    The inclination between the installation surface and the vertical plane should not exceed ±5°.
    Pollution level: level 3;
    The product should be installed in a place without obvious shaking, impact and vibration.

    Structural features of the product

    CJ40-63~1000 AC contactor adopts the structure of oven type, normal installation, direct acting and double breakpoints. The auxiliary contacts are installed on both sides of the main contact as independent components, which are electrically separated; The iron core is a U-shaped structure with the permanent air gap. The base is made of aluminum alloy die-casting (for CJ40-630A and above), which is installed by screws. But the base of CJ40-63~125 is made of unsaturated polyester glass fiber reinforced molding compound, which may be installed by screws or by “TH75” guide rail. With the advantages of high breaking capacity and high reliability, etc., the arc extinguishing chamber is made of arc resistant plastic and iron grid.

    Outline and installation dimensions

    CJ40 series AC contactor02

    Outline and installation dimensions of CJ40-63~1000 AC contactor

    Product type Outline dimensions (Max) Installation dimensions Installation rail Installation area F min
    A B C a b φ 380V 660v
    CJ40-63-125 116 143 154 100 90 5.8 Th75 20 40
    CJ40-160-200 146 186 184 130 130 9 - 30 40
    CJ40-250 40 60
    CJ40-315-400 190 235 230 160 150 9 40 60
    CJ40-500 50 70
    CJ40-630-1250 245 345 288 210 180 11 0 0
    CJ40-63/4~125/4 143 143 154 128 90 5.8 Th75 20 40
    CJ40-63/4~200/4 187 186 184 170 130 9 - 30 40
    CJ40-250-4 40 60
    CJ40-315/4~400/4 236 235 230 216 150 9 40 60
    CJ40-500/4 50 70

    Main parameters and technical performance

    Type and specification Frame code u A   th A leA under intermittent periodic work ing system AC-4 Pe kW under AC-3 leA nuder different intermittent working systems
    AC-1 AC-2 AC-3
    C40-63 125   220 80 80 63 63 63 18.5 80
    380 30
    CJ40-80 660  
    220 80 80 80  
    380  
    C140-100 660 63 63 63 55
    220 125 125 100 100 100 30 125
    380  
    CJ40-125 660 80 80 80  
    220 125 125 125  
    380 10  
    660 80 80 80  
    CJ40-160 250 690 220 250 250 160 160 160 45 250
    CJ40-200 380 75
    660 125 125 125 110
    220 200 200 200 55
    C40-250 380 90
    660 125 125 125 110
    220 250 250 250 75
    380 225 132
    660 125 125 125 110
    CJ40-315 500 690 220 500 500 315 315 315 90 500
    CJ40-400 380 250 160
    660 300
    CJ40-500 220 400 400 400 110
    380 315 220
    660 315 315 300
    220 500 500 500 150
    380 400 280
    660 315 315 315 300
    CJ40-630 1000 690 220 800 630 630 630 630 200 630
    CJ40-800 380 500 335
    C140-1000 660 500 500 500 475
    220 800 800 800 800 250 800
    380 630 450
    CJ40-1250 1250 660 500 500 500 475
    220 1000 1000 1000 1000 1000 360 1000
    380 550
    660 630 630 500 570
    220 1250 1250 1250 1250 1250 375 1250
    380 600
    660 800 800 600 630
    C40-125/11 1250 1140 1140 125 125 40 40 40 55 125
    C140-250/11 250 1140 250 250 80 80 80 110 250
    C140-500/11 500 1140 500 500 160 160 160 220 500
    CJ40-1000/11 1000 1140 1000 1000   400   600 1000

    Frequently Asked Questions (FAQ)

    Q1: What does the auxiliary code represent in the CJ40 series AC contactor?
    A1: The auxiliary code consists of 5 parts indicating the product type (general or reversible), the number of poles of the main circuit, the highest rated working voltage, the rated control power supply voltage (AC/DC), and the type/number of auxiliary contacts.
    Q2: What are the primary installation altitude and temperature requirements for this contactor?
    A2: The installation altitude should not exceed 2000m. The ambient air temperature must remain between -5℃ and +40℃ for normal working conditions.
    Q3: How does humidity affect the installation site of the CJ40 contactor?
    A3: At the maximum temperature of +40℃, relative humidity should not exceed 50%. Higher humidity is permitted at lower temperatures, but in the wettest month, the average minimum temperature should not exceed +20℃, and the average maximum relative humidity should not exceed 90%.
    Q4: What structural features define the CJ40-63~1000 AC contactor?
    A4: It features an oven-type structure, normal installation, direct acting, and double breakpoints. The auxiliary contacts are electrically separated and installed on both sides of the main contact as independent components.
    Q5: What materials are used for the base of the CJ40 series contactor?
    A5: The base of the CJ40-630A and above is made of aluminum alloy die-casting. For the CJ40-63~125 models, the base is constructed from unsaturated polyester glass fiber reinforced molding compound.
    Q6: Can the CJ40 contactor be installed on a guide rail?
    A6: Yes, the CJ40-63~125 models can be installed using either screws or a "TH75" guide rail, whereas the larger models are installed exclusively by screws.