This series of AC contactors, manufactured by leading suppliers in China, is designed for electric power systems operating at a frequency of 50Hz. With a rated working voltage of up to 690V and a rated current of up to 150A at 380V (and up to 100A at 690V) under the AC-3 usage category, these contactors effectively connect and disconnect circuits, as well as start and control AC motors with precision. When paired with an appropriate thermal overload relay or electronic protection device, they create an electromagnetic starter to safeguard circuits from potential overloads. Our products adhere to the strict executive standards of GB/T14048.4-2020 and IEC60947-4-1, ensuring reliability and efficiency for various applications. Trustworthy and durable, these AC contactors from our factory are essential for any robust electrical installation

    Type and meaning

    CJT1 series AC contactor

    Normal working conditions and installation conditions

    The altitude of the installation site should not exceed 2000m;
    The ambient air temperature should not be higher than +40℃ and not be lower than -5℃.
    When the highest temperature is +40℃, the relative humidity of the air on the installation site should not be higher than 50%: A higher relative humidity is allowed at a lower temperature: in the wettest month, the monthly average minimum temperature should not exceed +20℃, and the average maximum relative humidity should not exceed 90%. Measures should be taken for condensation on the product due to temperature change;
    The inclination between the installation surface and the vertical plane should not exceed ± 5°.
    Pollution level: level 3;
    The product should be installed in a place without obvious shaking, impact and vibration.

    Structural features of the product

    CJT1 series AC contactor (hereinafter referred to as the contactor) is a new CJ10 product which is improved and designed on the basis of the original CJ10 series AC contactor. It can replace the obsolete CJ10 series AC contactor. With the same outline and installation dimension as the original CJ10 system, the contactor has a greatly improved contact and arc extinguishing system so that its highest rated working voltage is increased from 380V to 690v; it has a DMC plastic arc extinguishing chamber replacing the clay one and is provided with an arc extinguishing piece; it is provided with an improved contact structure, which improves the arc extinguishing performance, prolongs the contact life, reduces the flash over distance and the product weight, and eliminates the problem that the clay chamber is damaged easily.

    Main parameters and technical performance

    For the basic parameters of the main circuit of the contactor, please refer to Table 1.
    The sucking coil of the contactor can work normally within the range of 85% ~ 110% of its rated control power supply voltage Us.
    Product type CJT1-10 CJT1-20 CJT1-40 CJT1-60 CJT1-100 CJT1-150
    Rated insulation voltage and working voltage V 380V
    Rated working current(AC-1-AC-4,380V) 10 20 40 60 100 150
    Control power kw 2.2 5.8 11 17 28 43
    4 10 20 30 50 75
    Number of operating cycles per hour times/h AC-1.AC- is 600.AC-2, AC-4 is 300, CJT1-150AC-4 is 120
    Electrical endurance 10,000 times 60
    2 1 0.6
    Mechanical endurance 10,000 times Normally open and normally closed 300
    Auxiliary contact 2 Normally Open 2 Normally Closed AC - 150180VA:DC - 1360W Ith:5A
    Matched fuse RT16-20 RT16-50 RT16-80 RT16-160 RT16-250 RT16-315
    Coil power consumption vA 65 140 230 485 760 950
    11 22 32 95 105 110

    Outline and installation dimensions

    For the outline and installation dimensions of the contactor, please refer to Figs.1, 2 and 3 and Table 2.
    The contactor is fixed and installed on a vertical plane with 3 screws, and its inclination should not exceed ±5° .
    CJT1 series AC contactor 02
    Fig.1 Outline and installation dimensions of CJT1-10

    Frequently Asked Questions (FAQ)

    Q: What is the difference between CJT1 and the older CJ10 series contactor?
    The CJT1 series is an improved replacement for the CJ10 series. It keeps the same outline and installation dimensions but features a greatly upgraded contact and arc extinguishing system, increasing the highest rated working voltage from 380V to 690V and replacing the clay chamber with a durable DMC plastic arc extinguishing chamber.
    Q: What are the installation altitude limitations for the CJT1 AC contactor?
    The altitude of the installation site for the CJT1 series AC contactor should not exceed 2000 meters to ensure normal operation.
    Q: What are the ambient temperature requirements for operating this contactor?
    The ambient air temperature must be maintained within the range of -5℃ to +40℃ for the safe and standard functioning of the product.
    Q: What is the allowable inclination angle for installing the contactor?
    The contactor should be installed on a vertical plane, and the inclination between the installation surface and the vertical plane must not exceed ±5°.
    Q: What is the working range of the sucking coil in the CJT1 contactor?
    The sucking coil of the contactor is designed to work normally within 85% to 110% of its rated control power supply voltage (Us).