China AC Contactor ZNFO Green Innovation Series - 95A Electric Motor Control Suppliers & Factory
Advantage
All products of the company can be customized for production according to user usage scenarios.
Type and meaning

Note l:
09A-95A adopts the number of auxiliary contacts, while 115A-800A adopts the number of poles.
11 means three normally open main contacts, one normally open auxiliary contact and one normally closed auxiliary contact.
Normal working conditions and installation conditions
⚙
The ambient air temperature should be -5℃ ~+40℃, with the average temperature of no higher than +35℃ within 24 hours.
⚙
Altitude: not higher than 2000m.
⚙
Atmospheric conditions: when the highest temperature is +40℃, the relative humidity of the air should not be higher than 50%; A higher relative humidity is allowed at a lower temperature, such as 90% under 20℃. Special measures should be taken for occasional condensation due to temperature change.
⚙
Pollution level: level 3.
⚙
Installation category: category III.
⚙
Installation condition: the inclination between the installation surface and the vertical plane should not exceed ±5°.
⚙
Impact vibration: the product should be installed and used in a place without obvious shaking, impact and vibration.
Main parameters and technical performance
Main parameters and technical performance indicators of the contactor:
| Type | ZHCt-0911 | ZHCt-1211 | ZHCt-1611 | ZHCt-1811 | ZHCt-2211 | ZHCt-2511 | ZHCt-3211 | ZHCt-3811 | ZHCt-4511 | ZHCt-5511 | ZHCt-7011 | ZHCt-8011 | ZHCt-10011 | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rated working current | 400(380)V | AC-3 | 9 | 12 | 16 | 18 | 22 | 25 | 32 | 38 | 45 | 55 | 70 | 85 | 100 |
| AC-4 | 3.5 | 5 | 6.5 | 7.7 | 8 | 8.5 | 12 | 15 | 18.5 | 24 | 28 | 37 | 44 | ||
| 690(660)V | AC-3 | 6.6 | 8.9 | 8.9 | 12 | 14 | 18 | 21 | 32 | 34 | 39 | 42 | 49 | 49 | |
| AC-4 | 1.5 | 2 | 3 | 3.8 | 4 | 4.4 | 7.5 | 8.5 | 9 | 12 | 14 | 17.3 | 21.3 | ||
| Conventional free air thermal current | 20 | 20 | 25 | 32 | 38 | 40 | 50 | 60 | 60 | 80 | 80 | 95 | 95 | ||
| Rated insulation voltage | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | ||
| Controllable three-phase squirrel cage motor power (AC-3) kW | 230(220)V | 2.2 | 3 | 3.5 | 4 | 5 | 5.5 | 7.5 | 10 | 11 | 15 | 18.5 | 22 | 25 | |
| 400(380)V | 4 | 5.5 | 7 | 7.5 | 10 | 11 | 15 | 18 | 18.5 | 22 | 30 | 37 | 45 | ||
| 690(660)V | 5.5 | 7.5 | 9 | 10 | 14 | 15 | 18.5 | 22 | 30 | 37 | 37 | 45 | 45 | ||
| Operating frequency (times/h) | Electrical / mechanical endurance | AC-3 | 1200 | 1200 | 1200 | 1200 | 1200 | 1200 | 1200 | 1200 | 600 | 600 | 600 | 600 | 600 |
| AC-4 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | ||
| Mech. | 3600 | 3600 | 3600 | 3600 | 3600 | 3600 | 3600 | 3600 | 3600 | 3600 | 3600 | 3600 | 3600 | ||
| Electrical endurance (10,000 times) | AC-3 | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 80 | 60 | 60 | 60 | 60 | |
| AC-4 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 | ||
Outline and installation dimensions

Outline and installation dimensions of ZHCt-09~32

Outline and installation dimensions of ZHCt-45~100
| Contactor type | A max | B max | C max | D max | E max | a | b | Φ |
|---|---|---|---|---|---|---|---|---|
| ZHCt-0911~1211 | 47 | 76 | 87 | 120.5 | 145.5 | 34/35 | 56/60 | 4.5 |
| ZHCt-1611~1811 | 47 | 76 | 87 | 125.5 | 145.5 | 34/35 | 50/60 | 4.5 |
| ZHCt-2211~2511 | 57 | 86 | 100 | 138.5 | 158.5 | 40 | 48 | 4.5 |
| ZHCt-3211~3811 | 57 | 86 | 100 | 138.5 | 158.5 | 40 | 48 | 4.5 |
| ZHCt-4511~7011 | 77 | 129 | 116 | 154.5 | 174.5 | 40 | 105 | 6.5 |
| ZHCt-4504~7004 | 84 | 129 | 116 | 154.5 | 174.5 | 40 | 105 | 6.5 |
| ZHCt-4508~7008 | 84 | 129 | 127 | 154.5 | 174.5 | 40 | 105 | 6.5 |
| ZHCt-8511~10011 | 87 | 129 | 127 | 165.5 | 185.5 | 40 | 105 | 6.5 |
| ZHCt-8504~10004 | 96 | 129 | 122 | 160.5 | 180.5 | 40 | 105 | 6.5 |
| ZHCt-8508~10008 | 96 | 129 | 135 | 160.5 | 180.5 | 40 | 105 | 6.5 |
Frequently Asked Questions
Can these contactors be customized for specific applications?
Yes, all products of the company can be customized for production according to the user's specific usage scenarios.
What does the auxiliary contact designation "11" mean for the ZHCt models?
The "11" designation means the contactor is equipped with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact.
What are the ambient temperature requirements for normal operation?
The ambient air temperature must remain between -5℃ and +40℃, and the average temperature over a 24-hour period should not exceed +35℃.
What is the maximum installation altitude and inclination allowed?
The contactors should be installed at an altitude no higher than 2000 meters, and the inclination between the installation surface and the vertical plane must not exceed ±5°.
How does humidity affect the working conditions of the contactors?
At a peak temperature of +40℃, the relative humidity should not exceed 50%. However, higher humidity levels (e.g., up to 90% at +20℃) are acceptable at lower temperatures, provided special measures are taken for occasional condensation.