Introducing the CJ19t Series Capacitor Changeover Contactor, an essential component designed for electric power circuits operating at frequencies of 50Hz (or 60Hz) and a rated voltage of up to 400V. This high-quality contactor is primarily utilized in activating or disconnecting low-voltage reactive power compensation equipment and low-voltage shunt capacitors, Our contactor features an advanced inrush current suppression device that effectively mitigates the effects of closing inrush currents on capacitors, ensuring enhanced durability and performance. This innovative feature also helps to suppress overvoltage during disconnection, making it a reliable choice for your electrical applications, As a leading supplier from China, our factory is committed to delivering top-notch electrical solutions that meet international standards. Trust our CJ19t Series to provide the performance and reliability you need in your power circuits

    Advantage

    All products of the company can be customized for production according to user usage scenarios.

    Type and meaning

    hkugtre

    Type and meaning

    Annotation:
    1. The number of auxiliary contacts is represented by two digits, of which the tens digit is the logarithm of normally open contacts, and the units digit is the logarithm of normally closed contacts.
    2. For AC-6b 400vAT, the rated working currents corresponding to various specification codes are 25(18A), 32(24A), 43(29A), 50(36A), 63(48A), 95(58A), 125(87A).

    Normal working conditions and installation conditions

    • The ambient air temperature should not exceed +40°C, with the average temperature of no higher than +35°C within 24 hours. The lower limit of the ambient air temperature should be -5°C. When the highest temperature is +40°C, the relative humidity of the air should not be higher than 50%. A higher relative humidity is allowed at a lower temperature.
    • The altitude of the installation site should not exceed 2000m;
    • Pollution level: level 3;
    • Installation category: category I;
    • Installation condition: the inclination between the installation surface of the contactor and the vertical plane should not exceed 5°.
    • Impact and vibration: the product should be installed in a place without obvious shaking, impact and vibration.

    Installation wiring diagram

    For the schematic diagram of wiring of CJ19t series, please refer to Fig.1.
    fgerv2
    L1~L3 should be connected to the power supply side; T1~T3 should be connected to the load side.

    Main parameters and technical performance

    CJ19t 25 32 43 63 95 115 150 170
    Rated insulation voltage(Ui)V 500V 690V
    Rated working voltage(Ue)V 220V/240V, 380V/400V
    Controllable capacitor Capacity(Qn)Kva 220V 6 9 10 15 28.8(240V) 34.5(240V) 46(240V) 52(240V)
    380V 12 18 20 30 50(400V) 60(400V) 80(400V) 90(400V)
    Conventional free air thermal current Ith 25 32 43 63 63 200 200 275
    Rated working current(AC-6b)Ie A 17 23 29 43 43 87 115 130
    Inrush current suppression capability 20Ie
    Control power supply voltage UsV 110, 127, 220, 380
    Auxiliary contact AC-15:360VA DC-13:33W Ith:10A
    Operating frequency times/h 120
    Electrical endurance 10,000 times 10 2
    Mechanical endurance 10,000 times 100 300
    Dimensions and type Outline dimensions Installation dimensions
    A B C D A B φ Card gauge
    CJ19t-25 76 47 125 120 35 50/60 4.5 35
    CJ19t-32 86 58 135 130 40 50/60
    CJ19t-43 86 58 135 130 40 50/60
    CJ19t-63 128 79 156 150 40 100/110 6.5 35/75
    CJ19t-80 128 87 160 200 40 100/110
    CJ19t-95 128 87 160 200 40 100/110

    Outline and installation dimensions

    The contactor may be installed by screws or card track.
    fgerv3
    Diagram of outline and installation dimensions of CJ19t-25,32,43
    Frequently Asked Questions (FAQ)
    Can the CJ19t series contactor products be customized?
    Yes, all products of the company can be customized for production according to the user's specific usage scenarios.
    What are the ambient temperature requirements for installation?
    The ambient air temperature must not exceed +40°C, and the average temperature over 24 hours should not exceed +35°C. The lower limit for the ambient air temperature is -5°C.
    What is the maximum installation altitude allowed for this contactor?
    The altitude of the installation site for the contactor should not exceed 2000 meters.
    How should the wiring sides (L1~L3 and T1~T3) be connected?
    L1~L3 must be connected to the power supply side, and T1~T3 must be connected to the load side.
    What are the supported installation methods for the contactor?
    The contactor can be installed using either screws or card track, provided the inclination between the installation surface and the vertical plane does not exceed 5°.
    What are the pollution level and installation category of the CJ19t series?
    The contactor is designed with a pollution level of level 3 and falls under installation category I.