Leave Your Message

China CJX8(B) AC Contactor 690V 370A - Reliable Suppliers from Factory for Motor Control and Protection

The CJX8(B) series AC contactor is a reliable solution for power circuits operating at 50Hz or 60Hz frequencies. With a maximum voltage of 690V and a rated current of up to 370A, this contactor is designed to connect and disconnect circuits remotely or control AC motors frequently. It also offers under-voltage protection, ensuring safe operation. Often utilized in conjunction with the JR29 series thermal relay, it forms a complete electromagnetic starter that provides essential overload and open-phase protection. For added functionality, the contactor can be equipped with mechanical interlocking to create a reversible contactor. As a leading factory and supplier in China, we ensure high-quality products that meet global standards for performance and durability

    Type and meaning

    CJX8 (B) series AC contactor

    Structural features of the product

    AC contactors of CJX8-30 and below adopt the “normal installation structure", that is, the contact system is at the front, and this system is at the back (near the installation surface: CiX8-37 and above adopt the "inverted structure", that is. the magnetic system is at the front and the main contact system is at the back.
    The moving contact is of bridge structure.For CIX8-105 and above, the main static contact can be separated from the main wiring, so it is not necessary to disassemble the main conductor when replacing the contact.For CIX8-9-25, there are four pairs of contacts (three pairs of main contacts and one pair of auxiliary contacts or four pars of main contacts).For CiX8-30 and above, the moving contact bracket is provided with three moving contacts, and the number of main contacts cannot be increased.
    CIX8-9~CJX8-25 AC contactor adopts enclosed natural arc extinguishing, C]X8-30-45 adopts ferromagnetic sheet for arc extinguishingCJX8-65 and above adopt ferromagnetic grid for arc extinguishing. All products adopt arc-resistant plastic arc chambers.
    CJX8-9~CJX8-30 AC contactor can be quickly installed on the 35mm installation rail conforming to IEC standards.This series of contactors can be provided with different types of auxiliary contacts to increase the convenience of use (see table).
    Executive standards:IEC60947-4-1,VDE0660,NFC63-110,NBNC63158,CE117-3,BS5425,NE50012,.GB14048. 4-2003

    Main parameters and technical performance

    Main parameters and technical performance indicators of the contactor
    Contactor type CJX8- 9 CJX8- 12 CJX8- 16 CJX8- 25 CJX8- 30 CJX8- 37 CJX8- 45 CJX8- 65 CJX8- 85 CJX8- 105 CJX8- 170 CJX8- 250 CJX8- 370

    Rated insulation voltage V

    690

    Conventional thermal Current A

    16 20 25 40 45 45 60 80 100 170 250 330 410
    Rated working current of AC3(A) 400V 9 12 16 25 30 37 45 65 85 105 170 250 370
    690V 3.5 4.9 6.7 13 17.5 21 25 45 55 82 118 170 268
    Rated control power of AC3(KW) 400V 4 5.5 7.5 11 15 18.5 22 33 45 55 90 132 200
    690V 3 4 5.5 11 15 18.5 22 40 50 75 110 160 250
    Coil power(VA/W) Starting 60/50 60/50 60/50 85/65 85/65 175/125 175/125 270/130 270/130 510/280 750/460 1100/600 1900/850
    Holding 9/2.2 9/2.2 9/2.2 10/3 10/3 22/5 22/5 30/8 30/8 32/9 60/15 66/16 100/27
    Coil voltage V AC 24、36、48、110、127、230、400、415
    DC 24、48、110、220
    Type and number of auxiliary contacts available (0~4个)CA7 ( 0 ~ 4 个 ) C A 7 (0~4个)CA11

    Outline and installation dimensions

    Type A B C D E F G H
    CJX8-105 118max 154max 137max 140±0.5 35±0.31 Φ6.5+018 Φ6.5±0.2 ≥15
    CJX8-170 134max 165max 152max 150±0.5 40±0.31 6+0.3 7.5±0.36 ≥15
    CJX8-250 166max 206max 192max 190±0.575 50±0.31 7±0.29 8.5±0.29 ≥15
    CJX8-370 202max 252max 221max 220±0.575 60±0.31 7±0.29 8.5±0.29 ≥15

    Frequently Asked Questions (FAQ)

    What is the difference in structure between CJX8-30 and CJX8-37 AC contactors?
    AC contactors of CJX8-30 and below adopt the "normal installation structure" with the contact system at the front and the magnetic system at the back. In contrast, CJX8-37 and above adopt the "inverted structure" where the magnetic system is at the front and the main contact system is at the back.
    Is it necessary to disassemble the main conductor when replacing contacts on larger CJX8 models?
    No, for CJX8-105 and above, the main static contact can be separated from the main wiring. This design makes it unnecessary to disassemble the main conductor when replacing the contacts.
    What arc extinguishing methods are used in the CJX8 series?
    CJX8-9 to CJX8-25 use enclosed natural arc extinguishing; CJX8-30 to 45 use ferromagnetic sheets; and CJX8-65 and above utilize ferromagnetic grids. Additionally, all products feature arc-resistant plastic arc chambers.
    Can these AC contactors be mounted on standard DIN rails?
    Yes, CJX8-9 to CJX8-30 AC contactors are designed for quick installation on standard 35mm installation rails conforming to IEC standards.
    Which international standards do the CJX8 series AC contactors comply with?
    The series complies with multiple standards including IEC60947-4-1, VDE0660, NFC63-110, NBNC63158, CE117-3, BS5425, NE50012, and GB14048.4-2003.

    Leave Your Message