0102030405
China Limit Switch HL Factory - High Performance Metal Case with Stainless Steel Rollers & 10A 250V, 500,000 Cycle Suppliers
Advantage
All products of the company can be customized for production according to user usage scenarios.
Working conditions
- 1. Altitude: The altitude of the installation location does not exceed 2,000 meters;
- 2. Medium temperature: The ambient air medium temperature is not higher than +75℃ and not lower than -25℃;
- 3. Relative humidity: The average relative air humidity in the wettest month of the installation location is not greater than 90% (the average minimum temperature in the month is not greater than +25°C);
- 4. Pollution level of environmental conditions: The pollution level of environmental conditions is Level III;
- 5. Installation category: The installation category is Category I;
- 6. Types of limit switches: Structural types are divided according to structural types: The structure of this product is rotary type, and the speed ratios are: 80:1, 40:1, and 20:1. Control loops are divided according to control loops: this limit switch can be equipped with up to 8 control loops.
Environmental Characteristics
| Category | Product | Components |
|---|---|---|
| Normative reference | IEC60947-5-1, EN60947-5-1, UL508, CSA C22-2N° 14 | |
| IEC60204-1, EN60204-1 | ||
| Ambient temperature | Operation: -25..+70°C | -25..+70°C |
| Storage: -40..+70°C | -40..+70°C | |
| Vibration resistance | Compliant with IEC60068-2-6 50Hz, 1.5mm Double-amplitude | |
| Shock resistance | Compliant with IEC60068-2-27 30GH, 18ms in any position | |
| Protection class | IP66 Comply with IEC60529 | |
| Mechanical life | 15,000,000 times | |
Characteristics of contact module
The limit switch housing is made of die-cast aluminum, and the surface is sprayed with aluminum powder alkyd heat-resistant paint. The contact of the limit switch is disconnected by the operating arm driving the shaft to make the cam on the shaft move. The cam and the adjustment sleeve on the shaft are evenly equipped with 24 teeth on the circumference of φ26. The cam angle can be adjusted as needed to achieve the required closing procedure. When adjusting, just remove the screws on the end cover and the adjustment sleeve. The rocker arm can also be adjusted arbitrarily within 360 degrees (every 15 degrees), see Figure 1.
The protection level of the limit switch is IP44
| Parameter | Specification | |
|---|---|---|
| Rated operating characteristics | Inductive load: AC15, B300 (Ue=240V, Ie=1.5A) DC-13, R300 (Ue=250V, Ie=0.1A) Resistive load: 250V 5A |
|
| Rated insulation voltage | Ui=500V, class of pollution is 3, comply with IEC 60947-1 Ui=300V, comply with UL508, CSA C22-2N° 14 |
|
| Insulation resistance | >1000 MΩ at 500V | |
| Operating frequency | 120 times/min | |
| Electrical life | 1,000,000 times AC-15 (Ue=240V, Ie=1.5A) | |
| Contact resistance | after ten million times of operation | |
| Model | TSA-001 | TSA-003 | TSA-012 | TSA-021 | TSA-031 | TSA-061/071/081 |
|---|---|---|---|---|---|---|
| Triggering | At the end | Convex trigger | Any moving part | |||
| Triggering type | ||||||
| Single stage 1C Single-pole Type Za |
|
= | ||||
| Contact operation | Contacts attract | Contacts separate | ||||
| Max triggering speed | 0.25m/s | 0.25m/s | 0.25m/s | 1.3m/s | 1.3m/s | 1.3m/s |
| Max triggering force | 800g | 800g | 800g | 400g | 400g | 400g |
| Min restoring force | 400g | 400g | 400g | 100g | 100g | 100g |
| Weight | 0.223 | 0.220 | 0.260 | 0.240 | 0.262 | 0.248 |
| Wiring | Each terminal can hold conductors of 2mm² at most | |||||
Overall and installation dimensions
Overall and installation dimensions
Frequently Asked Questions (FAQ)
Q1: Can these products be customized for specific applications?
Yes, all products of the company can be fully customized for production according to specific user usage scenarios.
Q2: What are the installation environmental limits for the limit switch?
The installation altitude must not exceed 2,000 meters. The ambient air temperature should be between -25°C and +75°C, and the average relative humidity in the wettest month must not exceed 90% (with an average minimum temperature in that month not exceeding +25°C).
Q3: What are the speed ratios and control loop configurations available?
The limit switch features a rotary structure with speed ratios of 80:1, 40:1, and 20:1. The system can be configured to accommodate up to 8 control loops.
Q4: What is the housing material and protection rating of the limit switch?
The housing is constructed from high-quality die-cast aluminum and finished with a surface spray of aluminum powder alkyd heat-resistant paint. The overall limit switch housing has a protection rating of IP44, while the environmental components meet IP66 standards.
Q5: How adjustable is the operating rocker arm?
The rocker arm can be adjusted arbitrarily within a full 360-degree range, with adjustment steps of 15 degrees.
Q6: What is the mechanical and electrical life expectancy of this equipment?
The equipment offers a high mechanical life of 15,000,000 operations and an electrical life of 1,000,000 operations under AC-15 (Ue=240V, Ie=1.5A) conditions.