China LX33 Crane Limit Switch - Reliable Suppliers & Factory for AC/DC Control Solutions
Advantage
All products of the company can be customized for production according to user usage scenarios.
Type Meaning
The limit switch is divided into the following forms according to different usage methods:
- LX33-1 rod-shaped operating arm automatic reset type, referred to as rod type;
- LX33-2 fork-shaped operating arm non-automatic reset type, referred to as fork type;
- LX33-3 heavy hammer type;
- LX33-4 rotary;
Working conditions
- 1) The upper limit of ambient air temperature is 40℃;
- 2) The lower limit of ambient air temperature is not lower than -5℃;
- 3) The 24-hour average ambient air temperature does not exceed 35 ℃.
Altitude: The altitude of the installation site does not exceed 2000m.
Mixing degree: The relative humidity of the air does not exceed 50% when the optimal temperature is 40°C. It can have higher relative humidity at lower temperatures. The monthly average minimum temperature of the wettest month does not exceed 25°C. The monthly average temperature of the wettest month does not exceed 25°C. The average maximum relative humidity does not exceed 90%. Condensation that occurs on products due to temperature changes requires action.
Mixing degree: The relative humidity of the air does not exceed 50% when the optimal temperature is 40°C. It can have higher relative humidity at lower temperatures. The monthly average minimum temperature of the wettest month does not exceed 25°C. The monthly average temperature of the wettest month does not exceed 25°C. The average maximum relative humidity does not exceed 90%. Condensation that occurs on products due to temperature changes requires action.
Construction Introduction
The travel switch is mainly composed of a contact group, a camshaft, a shell, etc. The contact breaking is realized by the rotation of the camshaft driven by a motor mechanism. The contact group structures are all rotary double breakpoints, rod type, fork type, and heavy bell type. The limit switch can be equipped with one or two sets of contact groups to form a single circuit (one normally closed) or a double circuit (one normally open, one normally closed) opening and closing form. In actual application, the user can adjust the cam angle as needed. You can change the contact opening and closing mode. The rotary limit switch can be installed with four contact groups at the same time, so that it can have secondary protection when it rises or falls. In practical applications of the rotary limit switch, if you need to control the lift of the lifting mechanism, you only need to pull out the positioning pin, turn the nut, and adjust the screw nut mechanism to change the lift of the lifting mechanism.
Pollution level: Level 3
Installation category: Category II
Main technical parameters
Rated working voltage
380V, DC 220V
Agreed heating current
10A
Rated operating frequency
300 times/hour
Mechanical life
Not less than 1 million times
Rated insulation voltage (Ui)
400V
Agreed heating current (Ith)
10A
Usage category
AC-15 DC-13
Ue/Ie (AC-15)
AC380V/2.6A
Ue/Ie (DC-13)
DC220V/0.4A
Shell protection grade
IP44
Equipped fuse model
RT16-10A
A contact group (2) is installed in the travel switch housing, and the moving contact and the stationary contact thereof drive the cam on the switch shaft (4) to open and close the contacts as the operating arm (3) rotates. The positioning of the operating arm is achieved by means of a positioning member (5), a positioning spring (6), a positioning lever (7) and a roller (8).
Use and maintenance
Use and maintenance
See Figure 5 and Figure 6 for appearance and installation dimensions.
Frequently Asked Questions (FAQ)
Can the limit switches be customized for specific scenarios?
Yes, all products of the company can be customized for production according to user usage scenarios.
What are the different types of LX33 limit switches available?
The LX33 limit switch is available in four forms: LX33-1 (rod type), LX33-2 (fork type), LX33-3 (heavy hammer type), and LX33-4 (rotary type).
What are the ambient temperature limits for operating these switches?
The ambient air temperature must have an upper limit of 40℃, a lower limit of not lower than -5℃, and a 24-hour average ambient temperature not exceeding 35℃.
What is the mechanical life and protection rating of the travel switch?
The mechanical life is not less than 1 million times, and the shell protection grade is IP44.
How does the contact group configuration work in the rotary limit switch?
The rotary limit switch can be installed with up to four contact groups simultaneously, allowing for secondary protection during rising or falling operations.