Advantage
Type Meaning
Working Conditions
- Altitude: The altitude of the installation location does not exceed 2,000 meters;
- Medium temperature: The ambient air medium temperature is not higher than +75℃ and not lower than -25℃;
- Relative humidity: The average relative air humidity in the wettest month of the installation location is not greater than 90% (the average minimum temperature in the month is not greater than +25°C);
- Pollution level of environmental conditions: The pollution level of environmental conditions is Level III;
- Installation category: The installation category is Category I;
- Types of limit switches: Structural types are divided according to structural types: The structure of this product is rotary type, and the speed ratios are: 80:1, 40:1, and 20:1. Control loops are divided according to control loops: this limit switch can be equipped with up to 8 control loops.
Basic Parameters
| Rated control capacity | Rated operating voltage | Rated operating current | Conventional thermal current | Rated operating frequency (Times/hour) | Rated insulation voltage |
|---|---|---|---|---|---|
| 300VA AC | 380 | 0.42 | 3 | 300 | 400 |
| 220 | 0.85 | ||||
| 10W DC | 220 | 0.15 | |||
| 110 | 0.07 |
Making and Breaking
The making and breaking capabilities of the limit switch are shown in Table 2
| Use Category | Rated operating current | On condition | Breaking conditions | ||||
|---|---|---|---|---|---|---|---|
| I(A) | U(V) | COSφ | Ic(A) | Ur(V) | COSφ or T0.95(ms) | ||
| AC-15 | 380V 0.42A | 0.8 | 418 | 0.7 | 8.8 | 418 | 0.7 |
| DC-13 | 220V 10W 0.15A | 0.05 | 242 | 300mS | 0.05 | 242 | 300mS |
Electrical Life
The electrical life of the limit switch is 100,000 flashes of load operation without the need for repairable replacement parts under the usage conditions listed in Table 3.
| Use Category | On condition | Breaking conditions | ||||
|---|---|---|---|---|---|---|
| I(A) | U(V) | COSφ | Ic(A) | Ur(V) | COSφ or T0.95(ms) | |
| AC-15 | 0.8 | 380 | 0.7 | 8.8 | 380 | 0.4 |
| DC-13 | 0.045 | 220 | 300mS | 0.045 | 220 | 300mS |
Mechanical Life
Speed Limit
The maximum speed of the input shaft end of the limit switch is 150r/min;
Grade
Contact numbers: The contact numbers of the control loop contacts are shown in the figure.

Construction Introduction
The limit switch is composed of a main shaft passing through a gear reduction system, a camshaft with an adjustable cam plate combination, and a control system composed of micro switches symmetrically arranged on both sides. The three components are integrated and installed in a housing with a protection level of IP54., its appearance and installation dimensions are shown in the figure.

Adjustment Cam plate Angle
Cam plate Angle: There are two types of cam plates and eight types, that is, the first type includes seven types including Ia, Id...Ig. There is only one type of Category II. Its working angle and corresponding rotation number of the limit switch spindle are shown in Table 4.
| Model | Speed | When micro switch contacts closed | Reference Dimensions | |||
|---|---|---|---|---|---|---|
| Cam plate type | Cam plate Maximum working angle | Limit switches Corresponding spindle revolutions | ||||
| LX36-88 | 80:1 | I | I | 338.6 | 75.2 | A |
| I | 336.6 | 74.8 | 0 | |||
| I | 334.6 | 74.3 | 1.5 | |||
| I | 332.6 | 73.9 | 2.4 | |||
| I | 330.6 | 73.4 | 3.2 | |||
| I | 328.6 | 73 | 4.0 | |||
| I | 326.6 | 72.5 | 4.8 | |||
| II | 175 | 38.8 | 5.7 | |||
| LX36-84 | 40:1 | I | I | 338.6 | 37.6 | |
| I | 336.6 | 37.4 | 0 | |||
| I | 334.6 | 37.1 | 1.5 | |||
| I | 332.6 | 36.9 | 2.4 | |||
| I | 330.6 | 36.7 | 3.2 | |||
| I | 328.6 | 36.5 | 4.0 | |||
| I | 326.6 | 36.2 | 4.8 | |||
| II | 175 | 19.4 | 5.7 | |||
| LX36-82 | 20:1 | I | I | 338.6 | 18.8 | |
| I | 336.6 | 18.7 | 0 | |||
| I | 334.6 | 18.5 | 1.5 | |||
| I | 332.6 | 18.4 | 2.4 | |||
| I | 330.6 | 18.3 | 3.2 | |||
| I | 328.6 | 18.2 | 4.0 | |||
| I | 326.6 | 18.1 | 4.8 | |||
| II | 175 | 9.7 | 5.7 | |||
A1: Yes. All of the company's products can be customized and produced based on the user's specific usage scenarios.
A2: The switch should be installed at an altitude not exceeding 2,000 meters, with ambient temperatures between -25°C and +75°C, and relative humidity not exceeding 90% in the wettest month (at a monthly average minimum temperature of +25°C).
A3: The limit switch structure is rotary with speed ratios of 80:1, 40:1, and 20:1. It can be equipped with up to 8 control loops.
A4: The limit switch has a mechanical life of 1 million operations and an electrical life of 100,000 cycles of load operations under specified conditions without needing replacement parts.
A5: The maximum rated speed of the input shaft end of the limit switch is 150 r/min.
A6: The switch is composed of a main shaft, a gear reduction system, an adjustable camshaft, and micro switches. These components are integrated into a protective housing rated at IP54.