Leave Your Message

DF1 Limit Switch

The DF1 series limit switch is suitable for use as the stroke limit and terminal protection of the translation mechanism of mobile machinery in control lines with AC 50HZ, rated operating voltage up to 380V, and DC rated operating voltage up to 220V. It complies with the GB/T14048.5-2017 standard.

    Advantage

    All products of the company can be customized for production according to user usage scenarios.

    Product overview


    The DF1 series limit switch is suitable for use as the stroke limit and terminal protection of the translation mechanism of mobile machinery in control lines with AC 50HZ, rated operating voltage up to 380V, and DC rated operating voltage up to 220V. It complies with the GB/T14048.5-2017 standard.

    Classification and model meaning

    Limit switches are divided into the following types according to different usage methods: rod-shaped operating arm automatic reset type, referred to as rod type; The fork-shaped operating arm is a non-automatic return type, referred to as the "also type".
    未标题-3
    Normal working conditions
    a) The maximum allowable temperature does not exceed 130°C;
    b) The minimum allowable temperature is not limited to -5℃;
    Altitude: The altitude of the installation site does not exceed 2000m.
    Pollution level: The pollution level of the limit switch is level 3 Installation category: The installation category of the limit switch is blood type.
    Installation conditions: The limit switch should be installed in accordance with the installation requirements in the instruction manual provided by the manufacturer.

    Construction Introduction


    The limit switch housing is made of die-cast aluminum, and the surface is sprayed with aluminum powder alkyd heat-resistant paint. The contact of the limit switch is disconnected by the operating arm driving the shaft to make the cam on the shaft move. The cam and the adjustment sleeve on the shaft are evenly equipped with 24 teeth on the circumference of φ26. The cam angle can be adjusted as needed to achieve the required closing procedure. When adjusting, just remove the screws on the end cover and the adjustment sleeve. The rocker arm can also be adjusted arbitrarily within 360 degrees (every 15 degrees), see Figure 1.
    The protection level of the limit switch is IP44

    Use and installation

    The deviation switch mounted on the bracket, and then welded to the tape rack.Edger A plane perpendicular to the axis of the tape, and the tape vertical roll edge distance of L = 50 100mm; Tape is located 1/3 lower end of the vertical roll; every deviation 50M tape can be mounted to open a pair.
    图片4

    Main Parameter

    Basic parameters
    The basic parameters of the limit switch are shown in Table 1

    Rated control capacity

    Rated operating voltage

    Rated operating current

    Conventional thermal current

    Rated operating frequency (Times/hour)

    Rated insulation voltage

    630VA

    AC

    380

    1.7

    10

    30

    500

    220

    3

    60W

    DC

    220

    0.27

    110

    0.54

    Making and breaking
    The connection and disconnection capacity of the limit switch is shown in Table 2

    Use Category

    Rated operating current

    On/Breaking condition

    AC-11

    1.7

    I(A)

    U(V)

    COS φ

    18.7

    418

    0.7

    DC-11

    0.27

    I(A)

    U(V)

    T0.95

    0.44

    242

    300mS

    Leave Your Message