- Altitude: The altitude of the installation location does not exceed 2,000 meters;
- Medium temperature: The ambient air medium temperature is not higher than +75℃ and not lower than -25℃;
- Relative humidity: The average relative air humidity in the wettest month of the installation location is not greater than 90% (the average minimum temperature in the month is not greater than +25°C);
- Pollution level of environmental conditions: The pollution level of environmental conditions is Level III;
- Installation category: The installation category is Category I;
- Types of limit switches: Structural types are divided according to structural types: The structure of this product is rotary type, and the speed ratios are: 80:1, 40:1, and 20:1. Control loops are divided according to control loops: this limit switch can be equipped with up to 8 control loops.
| Product | Components | |
|---|---|---|
| Normative reference | IEC60947-5-1, EN60947-5-1, UL508, CSA C22-2N° 14 | |
| IEC60204-1, EN60204-1 | ||
| Ambient temperature | Operation: -25..+70°C | |
| Storage: -40..+70°C | ||
| Vibration resistance | Compliant with IEC60068-2-6 50Hz, 1.5mm Double-amplitude | |
| Shock resistance | Compliant with IEC60068-2-27 30GH, 18ms in any position | |
| Protection class | IP66 Comply with IEC60529 | |
| Mechanical life | 15,000,000 times | |
The protection level of the limit switch is IP44.
| Rated operating characteristics | Inductive load AC15, B300 (Ue=240V, Ie=1.5A) DC-13, R300 (Ue=250V, Ie=0.1A) Resistive load: 250V 5A |
|
|---|---|---|
| Rated insulation voltage | Ui=500V, class of pollution is 3, comply with IEC 60947-1 Ui=300V, comply with UL508, CSA C22-2N° 14 |
|
| Insulation resistance | >1000 MΩ at 500V | |
| Operating frequency | 120 times/min | |
| Electrical life | 1,000,000 times AC-15 (Ue=240V, Ie=1.5A) | |
| Contact resistance | after ten million times of operation | |
| Model | TSA-001 | TSA-003 | TSA-012 | TSA-021 | TSA-031 | TSA-061/071/081 |
|---|---|---|---|---|---|---|
| Triggering | At the end | Convex trigger | Any moving part | |||
| Triggering type | ||||||
| Single stage 1C Single-pole Type Za |
|
= | ||||
| Contact operation | Contacts attract | Contacts separate | ||||
| Max triggering speed | 0.25m/s | 0.25m/s | 0.25m/s | 1.3m/s | 1.3m/s | 1.3m/s |
| Max triggering force | 800g | 800g | 800g | 400g | 400g | 400g |
| Min restoring force | 400g | 400g | 400g | 100g | 100g | 100g |
| Weight | 0.223 | 0.220 | 0.260 | 0.240 | 0.262 | 0.248 |
| Wiring | Each terminal can hold conductors of 2mm² at most | |||||
Yes, all products of the company can be customized for production according to the user's specific usage scenarios.
The installation location should have an altitude not exceeding 2,000 meters, an ambient air temperature between -25℃ and +75℃, and a maximum average relative humidity of 90% in the wettest month (with the average minimum temperature not exceeding +25°C).
The product features a rotary structure with available speed ratios of 80:1, 40:1, and 20:1. The limit switch can be equipped with up to 8 control loops.
The overall protection class is IP66 (complying with IEC60529), while the contact module housing specifically features a protection level of IP44.
The housing is made of die-cast aluminum with an aluminum powder alkyd heat-resistant paint coating. The rocker arm can be adjusted arbitrarily within 360 degrees in increments of 15 degrees.
The limit switch features a mechanical life of 15,000,000 times and an electrical life of 1,000,000 times under AC-15 (Ue=240V, Ie=1.5A) operating conditions.