0102030405
Premium Limit Switch HL - Metal Case, High Performance 10A 250V, China Suppliers, Reliable Factory
Advantage
All products of the company can be customized for production according to user usage scenarios.
Working conditions
1. Altitude
The altitude of the installation location does not exceed 2,000 meters.
2. Medium temperature
The ambient air medium temperature is not higher than +75℃ and not lower than -25℃.
3. Relative humidity
The average relative air humidity in the wettest month of the installation location is not greater than 90% (the average minimum temperature in the month is not greater than +25°C).
4. Pollution level
The pollution level of environmental conditions is Level III.
5. Installation category
The installation category is Category I.
6. Types of limit switches
Structural types: Rotary type with speed ratios of 80:1, 40:1, and 20:1. Control loops: Equipped with up to 8 control loops.
Environmental Characteristics
| Item | Product | Components |
|---|---|---|
| Normative reference | IEC60947-5-1, EN60947-5-1, UL508, CSA C22-2N° 14 | - |
| - | IEC60204-1, EN60204-1 | |
| Ambient temperature | Operation | -25..+70°C |
| Storage | -40..+70°C | |
| Vibration resistance | Compliant with IEC60068-2-6 50Hz, 1.5mm Double-amplitude | |
| Shock resistance | Compliant with IEC60068-2-27 30GH, 18ms in any position | |
| Protection class | IP66 Comply with IEC60529 | |
| Mechanical life | 15,000,000 times | |
Characteristics of contact module
The limit switch housing is made of die-cast aluminum, and the surface is sprayed with aluminum powder alkyd heat-resistant paint. The contact of the limit switch is disconnected by the operating arm driving the shaft to make the cam on the shaft move. The cam and the adjustment sleeve on the shaft are evenly equipped with 24 teeth on the circumference of φ26. The cam angle can be adjusted as needed to achieve the required closing procedure. When adjusting, just remove the screws on the end cover and the adjustment sleeve. The rocker arm can also be adjusted arbitrarily within 360 degrees (every 15 degrees), see Figure 1.
Protection level: The protection level of the limit switch is IP44.
Protection level: The protection level of the limit switch is IP44.
| Rated operating characteristics | Inductive load: AC15, B300 (Ue=240V, Ie=1.5A) | DC-13, R300 (Ue=250V, Ie=0.1A) Resistive load: 250V 5A |
|
|---|---|---|
| Rated insulation voltage | Ui=500V, class of pollution is 3, comply with IEC 60947-1 Ui=300V, comply with UL508, CSA C22-2N° 14 |
|
| Insulation resistance | >1000 MΩ at 500V | |
| Operating frequency | 120 times/min | |
| Electrical life | 1,000,000 times AC-15 (Ue=240V, Ie=1.5A) | |
| Contact resistance | after ten million times of operation | |
| Model | TSA-001 | TSA-003 | TSA-012 | TSA-021 | TSA-031 | TSA-061/071/081 |
|---|---|---|---|---|---|---|
| Triggering | At the end | Convex trigger | Any moving part | |||
| Triggering type | ||||||
| Single stage 1C Single-pole Type Za |
|
= | ||||
| Contact operation | Contacts attract | Contacts separate | ||||
| Max triggering speed | 0.25m/s | 0.25m/s | 0.25m/s | 1.3m/s | 1.3m/s | 1.3m/s |
| Max triggering force | 800g | 800g | 800g | 400g | 400g | 400g |
| Min restoring force | 400g | 400g | 400g | 100g | 100g | 100g |
| Weight | 0.223 | 0.220 | 0.260 | 0.240 | 0.262 | 0.248 |
| Wiring | Each terminal can hold conductors of 2mm² at most | |||||
Overall and installation dimensions
Frequently Asked Questions (FAQ)
Can these limit switches be customized for special applications?
Yes, all products can be custom-manufactured to match specific operating conditions and user usage scenarios.
What speed ratios and control loop configurations are available?
The rotary limit switch is available in speed ratios of 80:1, 40:1, and 20:1, and can be equipped with up to 8 control loops.
What are the environmental ratings and operating temperatures?
The device operates in ambient medium temperatures from -25°C to +75°C (operation ambient -25°C to +70°C; storage -40°C to +70°C) with IP66 overall protection (IEC 60529) and IP44 module housing protection.
How can the cam angle and rocker arm be adjusted?
The cam and adjustment sleeve have 24 teeth on the φ26 circumference for precise cam angle setting by removing the end cover and sleeve screws. The rocker arm is adjustable 360 degrees in 15-degree increments.
What is the mechanical and electrical life expectancy?
The limit switch provides a mechanical life of up to 15,000,000 operations and an electrical life of 1,000,000 operations under AC-15 (Ue=240V, Ie=1.5A) loading.
What wire size is supported by the terminals?
Each terminal is designed to accommodate conductors up to a maximum cross-section of 2mm².