Leave Your Message

TSA Limit Switch(ZNFO Special Series)

Hard metal housing, maximum rocker angle ±95%; extra-long mechanical life of 20 million times; stainless steel rollers, punches and springs; optional PG11 cable head.

    Advantage

    All products of the company can be customized for production according to user usage scenarios.

    Working conditions

    1. Altitude The altitude of the installation location does not exceed 2,000 meters;

    2. Medium temperature: The ambient air medium temperature is not higher than +75℃ and not lower than -25℃;

    3. Relative humidity: The average relative air humidity in the wettest month of the installation location is not greater than 90% (the average minimum temperature in the month is not greater than +25°C);

    4. Pollution level of environmental conditions: The pollution level of environmental conditions is Level III;

    5. Installation category The installation category is Category I;

    6. Types of limit switches: Structural types are divided according to structural types: The structure of this product is rotary type, and the speed ratios are: 80:1, 40:1, and 20:1. Control loops are divided according to control loops: this limit switch can be equipped with up to 8 control loops.

     

    Environmental Characteristics

     

    Normative reference

    Product

    IEC60947-5-1,EN60947-5-1,UL508,CSAC22-2N°14

    Components

    IEC60204-1,EN60204-1

     

     

    Ambient temperature

    Operation

    -25..+70℃

    Storage

    40..+70℃

    Vibration resistance

    Compliant with IEC60068-2-6

    50Hz,1.5mm Double-amplitude

    Shock resistance

    Compliant with IEC60068-2-27

    30GN,18ms in any position

    Protection class

    IP66 Comply with IEC60529

    Mechanical life

    15,000,000 times

     

    Characteristics of contact module

    Rated operating characteristics

    Inductive load

    AC15,B300(Ue=240V,le=1.5A)DC-13,R300(Ue=250V,le=0.1A)

    Resistive load:250V5A

    Rated insulation voltage

     

     

    Ui=500V,class of pollution is 3 ,comply with IEC 60947-1 Ui=300V,comply with UL508,CSA C22-2n°14

    Insulation resistance

    >1000MQ at 500V

    Operating frequency

    120times/min

    Electrical life

    1,000,000times AC-15(Ue=240V,le=1.5A)

    Contact resistance

    after ten milliontimes of operation

    Model

    TSA-001

    TSA-003

    TSA-012

    TSA-021

    TSA-031

    TSA-061/071/081

    Triggering

    At the end

    Convex trigger

     Any moving part

     

     

     

    Triggeing type

     

     

    picture-3-3

     

     

     

     

    picture-4-3

     

     

    picture-5-2

     

     

    picture-6-2

     

     

    picture-7-2

     

     

    3/13   4/14

    2/12

     

     

     

    Single stage1C/0

    Single-pole

    Type Za

    picture-8-2

    picture-9-2

    picture-10

    picture-11-2

    picture-12-1

    picture-13-1

    Contact operation

    Contacts attract              Contacts separate

    Max triggering speed

    0.25m/s

    0.25m/s

    0.25m/s

    1.3m/s

    1.3m/s

    1.3m/s

    Max triggering force

    800g

    800g

    800g

    400g

    400g

    400g

    Min restoring force

    400g

    400g

    400g

    100g

    100g

    100g

    Weight

    0.223

    0.220

    0.260

    0.240

    0.262

    0.248

    Wiring

    Each terminal can hold conductors of 2mm²at most

     


                                                                                                                                                                                                                 